SMART2200RXLTAA Eaton Tripp Lite 1950VA UPS with AVR
SMART2200RXLTAA Overview
The Eaton Tripp Lite SMART2200RXLTAA 1950VA UPS is a line-interactive uninterruptible power supply designed to provide reliable backup power and voltage protection for servers, network devices, storage systems, and high-end workstations. It delivers 1950VA/1950W capacity, pure sine wave output, and built-in Automatic Voltage Regulation (AVR) to correct voltage fluctuations without relying on battery power. Its 2U rack/tower design, LCD interface, USB and serial connectivity, and support for optional external battery packs make it suitable for data centers, server rooms, and other critical IT environments.
5,046.25 AED
Description
| Specification | Details |
|---|---|
| Brand | Eaton Tripp Lite |
| Model | SMART2200RXLTAA |
| UPS Type | Line-Interactive |
| Capacity | 1950VA / 1950W |
| Output Waveform | Pure Sine Wave |
| Nominal Voltage | 120V |
| Form Factor | 2U Rack/Tower |
| AVR | Yes |
| Battery Type | VRLA |
| Full Load Runtime | Up to 4 minutes |
| Half Load Runtime | Up to 12 minutes |
| Output Receptacles | 6 × NEMA 5-20R, 1 × NEMA L5-20R |
| Input Connection | NEMA 5-20P |
| External Battery Support | BP72VRXLTAA, up to 4 packs |
| Communication | USB, Serial |
| Network Management | WEBCARDLXE compatible |
| Warranty | 2-Year Limited |
Frequently Asked Questions
1. What is the SMART2200RXLTAA UPS?
The SMART2200RXLTAA is a 1950VA/1950W Eaton Tripp Lite SmartPro line-interactive UPS designed to provide battery backup, voltage regulation, and power protection for compatible IT equipment.
2. Does the SMART2200RXLTAA provide pure sine wave output?
Yes. It provides pure sine wave output in both AC and battery modes, making it suitable for servers, storage devices, networking equipment, and other sensitive electronics.
3. How does AVR work on this UPS?
Automatic Voltage Regulation corrects abnormal high or low input voltage conditions without switching to battery power, helping conserve battery capacity and extend battery life.
4. How much runtime does the 1950VA UPS provide?
Runtime depends on the connected load and battery condition. The UPS provides approximately 4 minutes at full 1950W load and up to 12 minutes at half load under specified conditions.
5. Can the UPS be installed as a rack or tower unit?
Yes. Its 2U design supports both rack-mount and tower configurations, making it suitable for server rooms, data centers, and other IT environments with different installation requirements.

Reviews
There are no reviews yet.